You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 70 Next »

Attention:

Please note that operations of the CTD (Conductivity-Temperature-Depth) watersampler requires experienced scientific staff on board. The system is not operated by the ship's crew. Announce operations with the CTD Watersampler to AWI-Logistics prior to the cruise and clarify the data transfer after the cruise.

Summary

CTD provided by AWI

vessel:polarstern:ctd_sbe9plus_321 (3214)

Manufacturer
Model
Serial No. PS
Type CTD
No images available.

Contacts

Name Institution Role
Benjamin Rabe Alfred-Wegener-Institute Data Provider
Mario Hoppmann Alfred-Wegener-Institute Editor
Sandra Tippenhauer Alfred-Wegener-Institute Principal Investigator, Editor
Antonia Immerz Alfred-Wegener-Institute Editor
Allison Fong Alfred-Wegener-Institute Editor
Alfred Wegener Institute for Polar and Marine Research Alfred Wegener Institute, Helmholz Centre for Polar and Marine Research Owner
Mats Granskog Norwegian Polar Institute Editor
Sinhue Torres-Valdes Alfred-Wegener-Institute Data Provider
Laura Wischnewski Alfred-Wegener-Institute Data Provider
Dorothea Bauch GEOMAR Data Provider
Ellen Damm AWI Data Provider
Clara Hoppe Alfred-Wegener-Institute Data Provider
Anders Torstensson Uppsala University Data Provider
Julia Grosse GEOMAR Data Provider
Kirstin Schulz Alfred-Wegener-Institute Data Provider
Zoe Koenig UIB Editor
Ying-Chih Fang AWI Editor
Pliet FIELAX GmbH Data Provider
Kuznetsov Editor
Hailong Liu Jiaotong-Universität Shanghai Data Provider
Lena Eggers Data Provider
Janin Schaffer Alfred-Wegener-Institute Editor
Ingo Schuffenhauer IOW Editor
Ulfsbo University of Gothenburg Data Provider
Katyanne Shoemaker University of Rhode Island Data Provider
Jacob Allerholt Alfred-Wegener-Institute Data Provider
Salar Karam University of Gothenburg Data Provider

Components

The system consits of the CTD underwater unit (SBE9), the CTD shipboard equipment (SBE11), the watersampler carousel (SBE32) with 24 x 12 liter bottles (OTE) and the data acquisition computer with installed data acquisition software Seasave (V7.23.1) and data processing software SBE Data Processing (V7.22.5) and ManageCTD.
The CTD underwater unit is equipped with 2 temperature (SBE3plus) and 2 conductivity (SBE4C) sensors by default, which are calibrated on a regular basis. Several external sensors are available, which can be used in water depth up to 6000m: altimeter (Benthos PSA-916D), Fluorometer (Dr. Haardt or Wetlabs EcoFLR), Oxygen sensor (SBE43), Transmissiometer (Weblabs CStar 25cm), mechanical bottom detector.

Subdevices

Name Model Serial Number
Altimeter PSA-916 n/a
Fl. Chla. Wetlabs FLRTD 1670
SBE11plus Deckunit (mit PAR) 794
SBE32 Water sampling frame 55
SBE3plus temperature sensor SBE3plus n/a
SBE4 conductivity sensor SBE4 n/a
SBE4 conductivity sensor SBE4 n/a
SBE43 oxygene sensor SBE43 n/a
SBE43 oxygene sensor 4016
SBE43 oxygene sensor 4019
SBE5 pump 2544
SBE5 pump 4316
SIO SUNA Nitrate profiler 732
Underwater Vision Profiler SN204 UVP 204

Position

No local frame definition available.

Data logging, storage and archiving

Logged parameters

No parameters available.

Central geographical ship's position and time standard

Time synchronising of the computers is regulated via Windows Domain affiliation. UTC time is supplied via NMEA telegram and processed by Seasave software.
Geographical position is supplied via NMEA telegram and processed by Seasave software.

Rawdata storage on board

Mass data: The ManageCTD software produces data files in the mass storage.

root directory

\\polsrv1\data01\CTD

directory name

CruiseNo
e.g.
ANT-XXVI-1

file name

several files in the following subdirectories:
btl
conf1
dsp
final
mat
odv
work

Data volume (MB per day) ca

50

Number of files per day ca

10

Data archiving on land

After the cruise, the operator transfers the measurement data along with required meta data to AWI after consultaion with the data scientist and AWI Logistics. Then, the data (including meta data) can be made available on https://www.pangaea.de/ (for authorized users only).

File format(s)

raw data: *.hex, *.bl, *.hdr, *.xmlcon; processed data: *.txt

Calibration certificates

YES

Location of certificates

PI (calibration data is stored in *.xmlcon file)

Documentation

No resources available.


  • No labels