Attention:
The absolute pressure transducer setra 278 is permantly installed in both aircraft as part of the Basic Meteorology module. Additionally, the pressure transducer is installed in nose booms used for turbulence measurements.
The pressure transducer does not operate below 500 hPa.
Summary
A setra 278 model is used for measuring absolute, barometric pressure at the nose of the aircraft or within the Turbulence Nose Boom. Measuring range is 500-1100mbar at -40 to +60 °C with a response time of <100msec and sampling rate of 100Hz.
Manufacturer | setra |
---|---|
Model | 278 |
Serial No. | n/a |
Type | pressure sensor |
REGISTRY-Link | ↪ REGISTRY (6884) |
Contacts
No contacts available.
Available devices and Specifications
Name | Model | Serial Number | REGISTRY-Link |
---|---|---|---|
Absolute pressure transducer | 278 | 4999332 | ↪ REGISTRY (6885) |
Absolute pressure transducer | 278 | 4999331 | ↪ REGISTRY (6886) |
Absolute pressure transducer | 278 | 7547828 | ↪ REGISTRY (6887) |
Absolute pressure transducer | 278 | 6597168 | ↪ REGISTRY (6888) |
Absolute pressure transducer | 278 | 4999333 | ↪ REGISTRY (6889) |
Absolute pressure transducer | 278 | 4999330 | ↪ REGISTRY (6890) |
Absolute pressure transducer | 278 | 6931473 | ↪ REGISTRY (6891) |
Specifications of setra 278 (without mounting)
Position
Info | Setra 278 absolute pressure transducer are installed in the nose pylon of the aircraft for the basic meteorology module as well as in the turbulence nose boom used for turbulence measurements. |
X | 0.0 none |
Y | 0.0 none |
Z | 0.0 none |
Data logging, storage and archiving
Logged parameter
Parameter | O2ARegistry Output Type | Unit |
---|---|---|
analog signal of static pressure | pressure | V |
Rawdata storage on board
Data archiving on land
DMS
Documentation
Also see https://sensor.awi.de/ for calibration certificates of the sensors.