Please note that the Magnetometer System can only be operated upon request. Request operations with the Magnetometer System to AWI-Logistics in sufficient time prior to the cruise.

Summary

Magnetometers are used to measure the earth magnetic field. The magnetometer on board of Polarstern is a vector magnetometer that measures the vector components of the magnetic field. It consists of an upper and a lower sensor.

ManufacturerMAGSON GmbH
ModelMFG-2S
Serial No.n/a
Typemagnetometer



Contacts

NameInstitutionRole
Graeme EaglesAlfred-Wegener Institute of Polar and Marine ResearchPrincipal Investigator
Graeme EaglesAlfred-Wegener Institute of Polar and Marine ResearchData Scientist
Thorsten EggersAlfred-Wegener-Institute for Polar and Marine ResearchEngineer In Charge
Alfred Wegener Institute for Polar and Marine ResearchAlfred Wegener Institute, Helmholz Centre for Polar and Marine ResearchOwner
polarstern dshipAlfred-Wegener-Institutedship connector

Components

The system consits of two fluxgate magnetometers mounted at the crows nest.

Subdevices

NameModelType
Magnetometer downMFG-2Smagnetometer
Magnetometer upMFG-2Smagnetometer

Position

Origin Description:xyz-position calculated from Alignment Survey Report (2016), located on mast platform
X:62.76 m
(X-0 is at the center of der rudder (ref. design drawing of the vessel), positive X-axis is forward and along vessel centerline)
Y:-0.067 m
(Y-0 at centerline, positive Y-axis is portside)
Z:38.323 m
(Z-0 is set to the lowest point of the keel, positive Z-axis is upwards)

Data logging, storage and archiving

Logged parameters

ParameterSensor Output TypeUnit
electronics temperature porttemperature°C
electronics temperature starbordtemperature°C
geomagnetic total field intensity portsidemagnetic fieldnT
geomagnetic total field intensity starbord sidemagnetic fieldnT
sensor temperature portsidetemperature°C
sensor temperature starbord sidetemperature°C
geomagnetic x-component starbord sidemagnetic fieldnT
geomagnetic x-component port sidemagnetic fieldnT
geomagnetic y-component starbord sidemagnetic fieldnT
geomagnetic y-component port sidemagnetic fieldnT
geomagnetic z-component starbord sidemagnetic fieldnT
geomagnetic z-component port sidemagnetic fieldnT
gyro headingattitudedegree
gyro pitchattitudedegree
gyro rollattitudedegree

Central geographical ship's position and time standard

Time stamp via NMEA telegram.
Geographical ship's position via NMEA telegram.

Rawdata storage on board

Data storage in DShip system.

Dship

Uncorrected measurement data.

Device name

magnetics

Parameters

electronics temperature port [°C]; electronics temperature starbord [°C]; FP [nT]; FS [nT]; gyro heading [deg]; gyro pitch [deg]; gyro roll [deg]; sensor temperature port [°C]; sensor temperature starbord [°C]; XP-component [nT]; XS-component [nT]; YP-component [nT]; YS-component [nT]; ZP-component [nT]; ZS-component [nT]

Data archiving on land

After the cruise the DShip data set can be extracted from https://dship.awi.de/.

File format(s)

*.txt

Calibration certificates

NO

Documentation

  • König, M. (2006): Processing of shipborne magnetometer data and revision of the timing and geometry of the Mesozoic break-up of Gondwana = Auswertung schiffsfester Magnetometerdaten und die Neubestimmung des Zeitpunktes und der Geometrie des Mesozoischen Aufbruchs von Gondwana , Berichte zur Polar- und Meeresforschung (Reports on Polar and Marine Research), Bremerhaven, Alfred Wegener Institute for Polar and Marine Research, 525 , 137 p. .