Summary

Magnetic measurements can reveal the strength and direction of the geomagnetic field. One or two Cesium magnetometers are mounted in a combination of nose and/or tail booms. In addition, a Fluxgate Magnetometer for attitude compensation is installed. The sensor system and real-time compensation are controlled by an external unit (AADC II) mounted in a rack. Magnetic base stations with Overhauser magnetometers are used for ground reference of the airborne measurements.

aircraft:bt-67:gsm19 (6815)


ManufacturerRMS Instruments, Scintrex Ltd., RMS Instruments
Modelsee subdevices
Serial No.n/a
Typemagnetometer



Contacts

NameInstitutionRole
Graeme EaglesAlfred-Wegener Institute of Polar and Marine ResearchDevice Contact

Available devices and Specifications

NameModelSerial Number
Automatic Aeromagnetic Digital CompensatorAADCII9903860
Cesium MagnetometerCS-39511042
Cesium MagnetometerCS-39503008
Cesium MagnetometerCS-39810135
Cesium MagnetometerCS-39808131
Cesium MagnetometerCS-31203404
Fluxgate MagnetometerTFM100G1E110
Fluxgate MagnetometerTFM100G1E999
Overhauser Magnetometer GSM-19GSM-1952498
Overhauser Magnetometer GSM-19GSM-1962673

Specifications of GEM Overhauser Magnetometer

Dimension Sensor (Diameter x L)

75 x 175 mm

Weight Sensor

1.0 kg

Dimension Console (L x W x H)

223 x 240 x 69 mm

Weight Sensor

2.1 kg

Data interface

serial interface (RS-232)


Position


Info
CS-3 Cesium Magnetometers are mounted in a tail and a nose boom respectively. Additionally, a fluxgate magnetometer is mounted close to the aileron. Electronics are stored in a rack.

Data logging, storage and archiving

Logged parameter

ParameterSensor Output TypeUnit
magnetic field compensatedmagnetic fieldnT
magnetic field rawmagnetic fieldnT
magnetic field uncompensatedmagnetic fieldnT
magnetic field totalmagnetic fieldnT
magnetic field x-componentmagnetic fieldnT
magnetic field y-componentmagnetic fieldnT
magnetic field z-componentmagnetic fieldnT

Rawdata storage on land

Overhauser magnetometer data are recorded for several days independantly and continously.

Data archiving on land

Base station data of the GEM Overhauser magnetometers are downloaded frequently and are made accessible via the external devices file system of the aircraft data managment system (DMS).