Summary
TSI thermal mass flowmeters incorporate a proprietary platinum sensor design for measuring gas flows in applications demanding fast response and high accuracy over a wide flow range.The TSI 4000 Series was designed for ultra-low pressure loss to minimize any undesirable effects the flowmeter can have on the readings when installed in-circuit. In the BT-67 aircraft they are used for monitoring air flow to the various instruments installed.
Sensor-Info: aircraft:bt-67:tsi_flow, 6798
Manufacturer | TSI |
---|---|
Model | 4043 |
Serial No. | n/a |
Type | not assigned |
Contacts
Available Devices and Specifications
Name | Model | Serial Number |
---|---|---|
Thermal Mass Flow Meter | 4043 | 40431349010 |
Thermal Mass Flow Meter | 4043 | 40431510009 |
Thermal Mass Flow Meter | 4043 | 40431640004 |
Thermal Mass Flow Meter | 4043 | 40431633006 |
Dimension Sensor (L x W x H) |
182 x 64 x 53 mm |
---|---|
Weight Sensor |
0.2 kg |
Power Supply |
7.5 VDC ±1.5 V |
Data interface |
RS-232 |
Position
Origin Description: | Flowmeters are installed upon need to monitor air flow within tubes to the various sensors for gas analyzes. |
Data logging, storage and archiving
Logged parameter
Parameter | Sensor Output Type | Unit |
---|---|---|
gas flow | flow | l/min |
temperature | temperature | °C |
static pressure | pressure | kPa |
Rawdata storage on board
During flight flowmeter data can be recorded on an external PC.
Data archiving on land
After the flight flowmeter data can be downloaded and stored within the land system of the aircraft data managment system (DMS).