Metadata (Metadata Plugin) |
---|
|
Multi-Sensor Core Loggers capture physical measurands of sediment cores automated and non-destructive. |
...
...
Manufacturer | Geotek Ltd. |
---|
Model | MSCL-S |
---|
...
...
...
...
...
Contacts
Role | Name |
---|
Principal Investigator | Frank Niessen |
Data Scientist | Catalina Gebhardt |
Engineer in Charge | Dietmar Penshorn | Data Scientist | Frank Niessen |
Components
Metadata (Metadata Plugin) |
---|
|
The system consits of the measuring bench with a ballscrew, which pushes core section past 6 to 7 sensors measuring Gamma Density, P-wave Velocity, Magnetic Susceptibility, Point Magnetic Susceptibility, Colour Spectrophotometry, Linescan Imaging and optional Natural Gamma Spectrometry. All sensors simultaneously acquire the data, which is displayed real-time during logging. The acquired data is stored locally in the electronics with simple user interface. |
Metadata (Metadata Plugin) |
---|
|
|| Sensor Type | Gamma Density Sensor | P-Wave System | Magnetic Susceptibility Loop Sensor MS2C | Magnetic Susceptibility Point Sensor MS2E | CM-700D Spectrophotometer | Geoscan V Linescan Imaging | optional: Natural Gamma Spectrometry ||
|| Manufacturer | Geotek Ltd. | Geotek Ltd. | Bartington Instruments| Bartington Instruments | Konica Minolta Measuring Instruments (Konica) | Geotek Ltd. | Geotek Ltd. ||
|| Components | Gamma ray source (137-Caesium source with energies at 0.662 MeV) \\ detector \\ sensor stand mount (alignment of source/detector with center of core) | Geotek ultrasonic (230 kHz) acoustic transducers \\ Laser micrometer \\ PRT temperature Probe | Magnetic Susceptibility Loop Sensor MS2C | Magnetic Susceptibility Point Sensor MS2E | CM-700D Spectrophotometer | Geoscan V Linescan Imaging Camera specifications: \\ Pixel Sensors: 1x 5K CGD \\ Visible or Ultraviolet light source \\ ADC resolution: 14 bits per colour channel \\ correlated double sampling with exposure control \\ max pixel rate: 3.2M pixels/sec \\ max scan rate: 200 lines/sec \\ down core resolution: upt ot 10 microns \\ camera control: auto focus, aperture and lighting \\ data transmission: gigabyte ethernet interface \\ Canon lens mount | three 3"x3" NaI(Tl) detectors with photomultiplier tube and Multi-Channel Analyser (MCA) \\ detector housings: 6" diameter lead shields \\ interface and electronics supplied in integrated 19" rack unit || |
Position
...
Data logging, storage and archiving
Logged parameters
Gamma Density, P-wave Velocity, Magnetic Susceptibility (Loop), Magnetic Susceptibility (Point), Colour Spectrophotometry, Geoscan V Linescan Imaging, optional: Natural Gamma Spectrometry
Central geographical ship's position and time standard
Metadata (Metadata Plugin) |
---|
|
No time synchronising. |
...
...
Rawdata storage on board
Metadata (Metadata Plugin) |
---|
|
Local storage on MSCL-S electronic. Operator is in charge of data backup.
|
Dship
Metadata (Metadata Plugin) |
---|
|
No data transfer to DShip. |
Data archiving on land
Metadata (Metadata Plugin) |
---|
0 | DataOnLand |
---|
Not implemented, responibility with respective user. |
Documentation
http://www.geotek.co.uk/products/mscl-s/
http://www.geotek.co.uk/products/gammadensity/
...
Documentation
...