Attention:


LMS-Q680i  is a CLASS 3R Laser Product. It operates in the near-infrared light. Direct exposure to the laser radiation is dangerous and may cause severe damage to eyes and skin.

DO NOT LOOK INTO THE TRANSMITTER LENS!

DO NOT POINT THE TRANSMITTER LENS AT PEOPLES EYES!


Operation of the LMS-Q680i requires experienced staff on board the aircraft.

Summary

The long-range airborne laser scanner makes use of a powerful laser source, multiple-time-around (MTA) processing, and digital full waveform analysis. This combination allows operation at varying flight altitudes and is therefore ideally suited for aerial survey of complex terrain.

Manufacturer Riegl
Model LMS-Q680i
Serial No. S9998082
Type laser scanner
REGISTRY-Link ↪ REGISTRY (6788)

Contacts

Name Institution Role
Veit Helm Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research Device Contact

Components and Specifications

The LMS-Q680i system comprises the laser scanner itself and a data recorder unit installed in a rack.

Specifications of LMS-Q680i (without mounting)


Position

InfoThe LMS-Q680i is installed in the underfloor of the aircraft looking downward. The data recorder unit is installed in a rack.
X0.0 none
(no description given)
Y0.0 none
(no description given)
Z0.0 none
(no description given)

Data logging, storage and archiving

Logged parameter

Parameter O2ARegistry Output Type Unit
time-of-flight distance measurements of infrared nanosecond laser pulses distance none

Rawdata storage on board

Data archiving on land

Documentation

Also see https://sensor.awi.de/ for calibration certificates of the sensors.