Attention:

During flight 4 Novatel OEMV DL-V3 GPS receiver are installed in a rack in the aircraft cabin. They provide high-resolution binary data.

Summary

Four GPS antennas are mounted in longitudinal direction to the fuselage and one at each wing tip. The receivers are Novatel OEMV-3 devices, which hold several serial interfaces as well as an USB- and a Network-interface. They are operated with a high resolution at 50Hz. The binary data are stored in the DMS component ADA-C1.

aircraft:bt-67:dl-v3 (6669)

Manufacturer Novatel
Model OEMV DL-V3
Serial No. n/a
Type GPS receiver

Contacts

No contacts available.

Available devices and Specifications

Name Model Serial Number
Novatel OEMV DL-V3 OEMV DL-V3 NBV07400022
Novatel OEMV DL-V3 OEMV DL-V3 NBV07080013
Novatel OEMV DL-V3 OEMV DL-V3 NBV10470011
Novatel OEMV DL-V3 OEMV DL-V3 NBV11280011
Novatel OEMV DL-V3 OEMV DL-V3 NBV11300003
Novatel OEMV DL-V3 OEMV DL-V3 NBV11300002
Novatel OEMV DL-V3 OEMV DL-V3 NBV11300006
Novatel OEMV DL-V3 OEMV DL-V3 NBV11280007
Novatel OEMV DL-V3 OEMV DL-V3 NBV11280012

Specifications of OEMV DL-V3 (without mounting)

Dimension (L x W x H)

185 x 163 x 76 mm

Weight

1.3 kg

Power Supply

9 - 28 VDC

Data interface

serial interface (RS-232)

Position

InfoFour Novatel DL-V3 GPS Receiver are installed in a rack. Each of them is connected to a single GPS antenna installed on the left and right wing tips as well as on the front and rear part of the cabin roof.

Data logging, storage and archiving

Logged parameter

No parameters available.

Rawdata storage on board

During flight binary OEMV DL-V3 data are stored within the aircraft onboard DMS system.

Data archiving on land

After the flight binary OEMV DL-V3 data are accessible via the land system of the aircraft data managment system (DMS).

DMS

Module name

B704 Scientific GPS devices

Device name

GPS2-5

Parameters

ErrorText; Status

Important!

Binary data can only be downloaded from the file access menu of land DMS.


Documentation