Attention:


LDM301 is equipped with two laser. The infrared laser for measurement operating at 905nm is a CLASS 1 Laser Product which is safe under reasonably foreseeable conditions of operation. The pilot laser is a CLASS 2 Laser Product operating in the visible red light at 635nm. It is not eye-safe!

DO NOT LOOK INTO THE TRANSMITTER LENS!

DO NOT POINT THE TRANSMITTER LENS AT OTHER PEOPLES EYES!

DO NOT LOOK AT THE LASER BEAM USING OPTICAL INSTRUMENTS!

Summary

The laser distance measurement device LDM301 enables the non-contact measurement of distances. The measurement range depends on the reflectivity and the surface of the measuring target. It ranges between 0.5 and 300 m for almost all natural surfaces. Measurement uncertainty ranges between +/-20 mm and +/0 60mm depending on output range. Operation temperature is -40 to +60°C.

Sensor-Info: aircraft:bt-67:ldm301, 6775



Manufacturer Astech
Model LDM301
Serial No. n/a
Type laser distance meter


Available devices and Specifications

Name Model Serial Number
Laser Distance Meter LDM301 LDM301 100092
Laser Distance Meter LDM301 LDM301 170118

Specifications of LDM301 (without mounting)

Dimension (L x W x H)

136 x 57 x 104 mm

Weight

0.8 kg

Power Supply

10 - 30 VDC

Data Interface

RS-232 or RS-422

Position

Origin Description:The Laser Distance Meter LDM301 is installed in the underfloor compartment of the aircraft looking downward.

Data logging, storage and archiving

Logged parameter

Parameter Sensor Output Type Unit
distance between surface and aircraft distance m

Rawdata storage on board

During flight LDM301 data are stored within the aircraft DMS system.

Data archiving on land

After the flight LDM301 data are accessible via the land system of the aircraft data managment system (DMS).

DMS

Module name

B838 Altimeter LDM301

Device name

LDM301

Parameters

Distance [m]; ErrorText; LDM301 ASCII; SignalQuality; Status; Temperature [°C]