You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

Summary

Most of the scientific activities can only be carried out with the usage of winches. Therefore the winches are among the most important devices onboard. The winch concept aims to redundancy and flexibility. Smooth operation is overseen by the ship's engineers.


Contacts

NameInstitutionRole
Reederei BrieseReederei BrieseEngineer In Charge

Components

Following winches are used onboard:

W1-W4

4-drum winches

W5

trawl line winch starboard

W6

trawl line winch portside (net reel is installed between W5 and W6)

W8

auxiliary winch on stern boom

The winches are hydraulic and are powered by a central hydraulic unit. A side boom is installed on the starboard side for keeping winches and cables on the outboard. The side boom operates one of the 4 wires of the drum winches on the starboard side. Astern the cables are lead outboard via the stern boom.

4-drum winches


capacity intermediate rope layermax. rope speed intermediate rope layer slip ring transmitter
W120 kN0..120m/minyes

W2

30 kN0..80m/minno
W330 kN0..80m/minyes
W420 kN0..120m/minyes

Trawl line winches


capacity intermediate rope layermax. rope speed intermediate rope layer slip ring transmitter
W5 and W640 kN0..60m/minno

Auxiliary winch on stern boom


capacity intermediate rope layermax. rope speed intermediate rope layer slip ring transmitter
W830 kN0..40m/minno

Wiring

State of June 2015

W1

8mm-single conductor wire, length 2070m, 9.2 Ohm/km, connector SubConn IL-2-F (female) requiring IL-2-M (male) connector on the device side

W2

6mm-wire, length 2750m, steel wire Niro, 20kN breaking force

W3

11mm-single conductor wire, length 890m, 19 Ohm/km, connector SubConn IL-2-F (female) requiring IL-2-M (male) connector on the device side

W4

11mm-single conductor wire, length 1760m, 19 Ohm/km, connector SubConn IL-2-F (female) requiring IL-2-M (male) connector on the device side

W5 and W6

18mm-steel wire, length 2400m on each starboard side and portside

W8

16mm-galvanised steel wire, length 40m


Applying to all single conductor wires:  The single conductor wires are lead via a Ramert slip ring transmitter and a RG214U-cable into the Mess- und Registrierraum where the signal can be tapped at normal sockets. Slip ring transmitters are maintained yearly.





  • No labels