Plain-text table having columns for each parameter from your raw data files and rows for each individual time record.
A sample file is attached: nrtformat2-sample_adcp_20190217_235334.nrt ferrybox_raw_SVL_20190219_230002_ferrybox-731101.nrtraw

WhatHow
Character encoding

UTF-8

Field / column separatorTabulator “\t”
End of record markerNew line “\n”
Header

The header must consist of a column named “datetime” and 1-n columns having a static name describing your raw parameter.
If you convert from a different table-like dataset your driver could also take over the raw column headers.
The “datetime” column must always be the first column.

datetime    TEMP    SAL

Header - Units

Units may be given in square brackets [], following each raw parameter, separated by a space “ “:

datetime    TEMP [°C]    SAL [psu]

Units are optional but really make sense in this very first step because in the INGEST-to-DASHBOARD workflow they would be automatically
appended to the data.

If you desire to store texts such as sample numbers or comments in your file, you have to append a unit \[text\]!

Date time format

Expected time zone: UTC

Allowed date formats:

yyyy-mm-dd HH:MM:SS.fff
yyyy-mm-dd HH:MM:SS
yyyy-mm-ddTHH:MM:SS.fff
yyyy-mm-ddTHH:MM:SS

Decimal symbolDot "."
Data values

Decimal values, integer numbers or characters (just no tabulators!)

34.56556    23    334.43E-2    SAMPLE1

For use of Data-WS only: The Data-WS only accepts numbers as input for each column (including number formats such as 334.43E-2) .
If you want to store texts, the column's unit must be \[text\]!
For columns which do not have the unit \[text\] all characters or words (such as “inf”, “NaN”, “SAMPLE1”) will result in an import error.

Error valuesEmpty field (simply give a null string, but do not forget to add tabs as data field separator)