Note |
---|
|
Please note that the system can only be operated upon request. Operations with the MSCL-S requires experienced scientific staff on board. The system is not operated by the ship's crew. Announce operations with the MSCL-S to AWI-Logistics prior to the cruise and clarify the data transfer after the cruise. |
Summary
Metadata (Metadata Plugin) |
---|
|
Multi-Sensor Core Loggers capture physical measurands of sediment cores automated and non-destructive. |
![](/download/attachments/234225740/MSCL-S_x1000px.jpg?version=1&modificationDate=1512401231000&api=v2)
Metadata (Metadata Plugin) |
---|
|
*Manufacturer*: Geotek Ltd.
*Model*: MSCL-S
*Serial No*: 25
*Type*: Multi-Sensor Core Logger |
Role | Name |
---|
Principal Investigator | Frank Niessen |
Data Scientist | Catalina Gebhardt |
Engineer in Charge | Dietmar Penshorn |
Components
Metadata (Metadata Plugin) |
---|
|
The system consits of the measuring bench with a ballscrew, which pushes core section past 5 sensors measuring Gamma Density, P-wave Velocity, Magnetic Susceptibility (Loop and Point), Non-Contact Resistivity (NCR). All sensors simultaneously acquire the data, which is displayed real-time during logging. The acquired data is stored locally in the electronics with simple user interface. |
Metadata (Metadata Plugin) |
---|
|
|| Sensor Type | Gamma Density Sensor | P-Wave System | Magnetic Susceptibility Loop Sensor MS2C | Magnetic Susceptibility Point Sensor MS2F | Non-Contact Resistivity Sensor (NCR)||
|| Manufacturer | Geotek Ltd. | Geotek Ltd. | Bartington Instruments | Bartington Instruments | Geotek Ltd. ||
|| Components | Gamma ray source (137-Caesium source with energies at 0.662 MeV) \\ detector \\ sensor stand mount (alignment of source/detector with center of core) | Geotek ultrasonic (230 kHz) acoustic transducers \\ Laser micrometer \\ PRT temperature Probe | Magnetic Susceptibility Loop Sensor MS2C | Magnetic Susceptibility Point Sensor MS2F | transmitter coil (inducing a high-frequency magnetic field) \\ receiver coil ||
|
Data logging, storage and archiving
Logged parameters
Gamma Density, P-wave Velocity, Magnetic Susceptibility (Loop and Point), Non-Contact Resistivity
Rawdata storage on board
Metadata (Metadata Plugin) |
---|
|
Local storage on MSCL-S electronic. Operator is in charge of data backup.
|
Documentation
http://www.geotek.co.uk/products/mscl-s/
http://www.geotek.co.uk/products/gammadensity/
http://www.geotek.co.uk/wp-content/uploads/2017/06/Discrete_P-wave_System.pdf
http://www.bartington.com/presentation/ms2-ms3-magnetic-susceptibility-system?A=SearchResult&SearchID=2471066&ObjectID=5113146&ObjectType=35
http://www.geotek.co.uk/products/ncr/