Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Note
titleAttention:
Please note that the system can only be operated upon request. Operations with the MSCL-NG requires experienced scientific staff on board. The system is not operated by the ship's crew. Announce operations with the MSCL-NG to AWI-Logistics prior to the cruise and clarify the data transfer after the cruise.

Summary

Metadata (Metadata Plugin)
0Summary
Multi-Sensor Core Logger - Natural Gamma System is a stand-alone natural gamma system designed to obtain both total and full spectral natural gamma data. For high resolution and quality spectral data from sedimentary rocks the system is configured with three NaI(Tl) detectors.


...

0Description

...

ManufacturerGeotek Ltd.
ModelMSCL-NG

...

Serial

...

Non/a
TypeMulti-Sensor

...

Core

...

Logger-Natural

...

Gamma

...

System

Contacts

RoleName
Principal InvestigatorFrank Niessen
Data ScientistCatalina Gebhardt
Engineer in ChargeDietmar PenshornData ScientistFrank Niessen

Components

Metadata (Metadata Plugin)
0Components
The sensor comprises three 3"x3" NaI(Tl) detectors housed in 6" diameter lead shields. Each detector uses a NaI(Tl) crystal optically coupled to a photomultiplier tube and a Multi-Channel Analyser (MCA). The detectors make measurements over 1024 channels calibrated to correspond to 0-3 MeV energy range. The complete system is controlled through custom-designed Geotek MSCL software, which enables either multi-channel spectral measurements or simply total counts to be recorded. The software gives the user full control of sampling positions and intervals down the core and control of count times. All the electronics are supplied in a single integrated 19" rack unit that contains of all the necessary external electronics including the motor control unit, the microprocessor and rack mounted PC.
Metadata (Metadata Plugin)
0Sensors
|| Sensor Type |  MSCL-NG Natural Gamma System||
|| Manufacturer | Geotek Ltd. ||
|| Components | three 3"x3" NaI(Tl) detectors  with photomultiplier tube and Multi-Channel Analyser (MCA) \\ detector housings: 6" diameter lead shields \\ interface and electronics supplied in integrated 19" rack unit ||

Position

No fix onboard location.

Data logging, storage and archiving

Logged parameters

total and full spectral natural gamma data

Central geographical ship's position and time standard

Metadata (Metadata Plugin)
0timestandard
No time synchronising.

...

0shipsposition

...

Rawdata storage on board

Metadata (Metadata Plugin)
0Rawdata
Local storage on MSCL-NG electronic. Operator is in charge of data backup.

Dship

Metadata (Metadata Plugin)
0DShip
No data transfer to DShip.

Data archiving on land

Metadata (Metadata Plugin)
0DataOnLand
Not implemented, responibility with respective user.

Documentation

...