Please note that operations of the LI-7200 CO2 / H2O Analyzer requires experienced scientific staff on board the aircraft.

Summary

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeSummary

The Greenhouse Gas Analyzer (model GGA-24EP) is an advanced instrument for simultaneous measurements of methane (CH4), carbon dioxide (CO2) and water vapor (H2O) using cavity enhanced laser LI-COR CO2 Analyzer is measuring CO2 in the atmosphere using the non-dispersive, closed path infrared absorption technique.


Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeMetadata
Manufacturer
Droplet Measurement Technologies
LI-COR Biosciences
Model
UHSAS
LI-7200
Serial No.
1206
72H-
036
0584
Type
Spectrometer
CO2 analyser
REGISTRY-Link↪ REGISTRY (6792)


Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeImages

Image Removed Image Removed Image Removed Image RemovedImage Added Image Added Image Added

Contacts

Alfred-Wegener-Institute
Sensorweb integration
urnaircraft:bt-67:licor72hlicor_72h-0584
contenttypeContacts
Name Institution Role
Gerd Rohardt
Jörg HartmannAlfred
-
Wegener
-Institute
Data ScientistAndreas Wisotzky
Institute, Helmholtz Centre for Polar and Marine Research
Data ScientistFIELAX GmbHFIELAX Gesellschaft für wissenschaftliche Datenverarbeitung mbHEngineer In Charge
Device Contact

Components

The LI-7200 CO2 / H2O Analyzer system comprises the gas analyser itself and an interface unit for data flow.the LI-7550 Analyzer Interface Unit

Specifications of LI-7200 (without mounting)

Metadata list

Position

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeLocalFrame
Origin Description:
InfoThe
device is installed in a rack. It is connected with tubes to an air inlet installed at the cabin roof.
LI-7200 CO2 / H2O Analyzer is installed at the cabin ceiling were it is connected to the air flow system. The interface unit is installed in a rack.
X0.0 none
(no description given)
Y0.0 none
(no description given)
Z0.0 none
(no description given)

Data logging, storage and archiving

...

PSU
Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeParameters
Parameter
Sensor
O2ARegistry Output Type Unit
conductivity
CO2 absorptance
conductivity
CO2
Hz
internal temperaturetemperatureHz
external temperaturewater temperatureHz
first voltagevoltageV
second voltagevoltageV
Salinitysalinity
μmol/m3
H2O absorptancevolumetric water content μmol/m3
Temperaturetemperature°C
PressurepressurekPa

Rawdata storage on board

Metadata (Metadata Plugin)
0Rawdata
During flight LI-7200 data are stored within the aircraft DMS system.

Data archiving on land

Metadata (Metadata Plugin)
0DataOnLand
After the flight LI-7200 are stored within the land system of the aircraft data managment system (DMS). 

DMS

Metadata list
|| Module name| B897 LICOR||
|| Device name | Li_Cor 7200||
|| Parameters | APres \[kPa \]; CO2AW; CO2AWO; CO2D \[mmol m-3 \]; CO2MF \[µmol/mol \]; CO2Raw; CO2SS; Cooler \[V \]; DPres \[kPa \]; Date; DewPt \[°C \]; DiagVal; DiagVal2; ErrorText; H2OAW; H2OAWO; H2OG \[g/m-3 \]; H2OMF \[µmol/mol \]; H2ORaw; H2OSS; NMEA messages LICOR 7200; Ndx; Status; Temp \[°C \]; TempIn \[°C \]; TempOut \[°C \]; Time ||



Documentation

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeResources