Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeMetadata
Spectrometer
ManufacturerOcean Optics
ModelNIR Quest and QE65000
Serial No.n/a
Typespectrometer
REGISTRY-Link↪ REGISTRY (6745)


Sensorweb integration
urnaircraft:bt-67:ocean_optics:nir_nq52a0060
contenttypeImages

Image Added Image Added


Sensorweb integration
urnaircraft:bt-67:ocean_optics:vis_qea0158
contenttypeImages

No images available.

Image Added Image Added

Contacts


Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeContacts
Name Institution Role
Gerit BirnbaumAlfred -Wegener-InstitutEditorGerit BirnbaumAlfred-Wegener-InstitutWegener Institute, Helmholtz Centre for Polar and Marine ResearchDevice Contact

Available devices and Specifications

The Ocean Optics NIRQuest NIR spectrometers and QE65000 spectrometer are usually installed simultaneously. The fibre optics sensors are installed at the cabin roof looking upward or in the floor compartment looking downward. The They are connected to the spectrometers by fibre optics cables. Data aquisition is controlled by an operator PC installed in a rack. A DC/DC converter also installed in a rack provides the required voltage of 5 VDC for the spectrometers.

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeSubdevices
Name Model Type Serial Number REGISTRY-Link
NIRQuest SpectrometerNIRQuestSpectrometer NQ52A0060↪ REGISTRY (6746)
NIRQuest SpectrometerNIRQuestSpectrometer NQ52A0061↪ REGISTRY (6748)
Ocean Optics QE65000 Spectrometer QE65000Spectrometer QEA0158↪ REGISTRY (6751)
Ocean Optics QE65000 Spectrometer QE65000Spectrometer QEB0006↪ REGISTRY (6753)

Specifications of

...

Ocean Optics Spectrometer (without mounting)

Metadata list
|| Dimension Spectrometer (L x W x H)| 185 x 115 x 50 mm ||
|| Weight Spectrometer | 1.2 kg||
|| Power Supply| 4.5 – 5.5 VDC ||
|| Data interface | analog output (0-20mA) and serial interface (RS232)||

Position

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeLocalFrame
Origin Description:InfoThe spectrometers are installed in a rack. They are connected to the sensors via fibre optic cables. The sensors can be installed upward looking in the cabin roof or downward looking at the fuselage.
X0.0 none
(no description given)
Y0.0 none
(no description given)
Z0.0 none
(no description given)

Data logging, storage and archiving

...

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeParameters
Parameter O2ARegistry Output Type Unit
Visible light spectraspectral radiancenone
Near Infra-Red light spectraspectral radiancenone
No parameters found in sensor.awi.de.

Rawdata storage on board

During flight spectrometer data are stored on the operator PC.
Metadata (Metadata Plugin)
0Rawdata

Data archiving on land

After the flight spectrometer data have to be downloaded and are stored within the external devices file system of the aircraft data managment system (DMS).
Metadata (Metadata Plugin)
0DataOnLand

Documentation

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeResources

...