Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Automatically updated by Registry2Confluence-Transporter (aircrafts@ingestsrv1, ask o2a-support@awi.de for questions)

...

Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeSummary

The LI-COR CO2 Analyzer is measuring CO2 in the atmosphere using the non-dispersive, closed path infrared absorption technique.

Sensor-Info: aircraft:bt-67:tsi_flow, 6792

TSI thermal mass flowmeters incorporate a proprietary platinum sensor design for measuring gas flows in applications demanding fast response and high accuracy over a wide flow range.The TSI 4000 Series was designed for ultra-low pressure loss to minimize any undesirable effects the flowmeter can have on the readings when installed in-circuit. In the BT-67 aircraft they are used for monitoring air flow to the various instruments installed.


Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeMetadata
Manufacturer
LI-COR Biosciences
TSI
Model
LI-7200
4043
Serial No.
72H-0584
n/a
Type
CO2 analyser
not assigned
REGISTRY-Link↪ REGISTRY (6798)


Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeImages

Image Removed Image Removed Image RemovedImage Added

Contacts

Device Contact

No contacts available.

Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeContacts
NameInstitutionRole
Jörg HartmannAlfred-Wegener-Institut

Available Devices and Specifications

Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeSubdevices
Name Model Serial Number REGISTRY-Link
Thermal Mass Flow Meter404340431349010↪ REGISTRY (6799)
Thermal Mass Flow Meter404340431510009↪ REGISTRY (6800)
Thermal Mass Flow Meter404340431640004↪ REGISTRY (6801)
Thermal Mass Flow Meter404340431633006↪ REGISTRY (6802)


|| Dimension Sensor (L x W x H)| 182 x 64 x 53 mm|| || Weight Sensor | 0.2 kg|| || Power Supply | 7.5 VDC ±1.5 V || || Data interface | RS-232 ||
Metadata list
Metadata list

Position

The LI-7200 CO2 / H2O Analyzer is installed at the cabin ceiling were it is connected to the air flow system. The interface unit is installed in a rack.
Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeLocalFrame
InfoFlowmeters are installed upon need to monitor air flow within tubes to the various sensors for gas analyzes.
X0.0 none
(no description given)
Y0.0 none
(no description given)
Z0.0 none
(no description given)
Origin Description:

Data logging, storage and archiving

...

Temperature
Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeParameters
Parameter
Sensor
O2ARegistry Output Type Unit
CO2 absorptance
gas flow
CO2
flow
mmol
l/
m^3
H2O absorptancevolumetric water contentmmol/m^3
min
temperaturetemperature°C
Pressure
static pressurepressurekPa

Rawdata storage on board

Metadata (Metadata Plugin)
0Rawdata
During flight flowmeter data can be recorded on an external PC.

Data archiving on land

Metadata (Metadata Plugin)
0DataOnLand
After the flight flowmeter data can be downloaded and stored within the land system of the aircraft data managment system (DMS). 

Documentation

Sensorweb integration
urnaircraft:bt-67:tsi_flow
contenttypeResources