Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeSummary

Multibeam EM712 is a high-resolution seafloor mapping system. It is suitable for water depths up to 2000m depending on the configuration of the transducers. Maximum ping rate is 30Hz and maximum fan width 140° 140° and depth resolution 1cm. Data from the water column may also be stored.

...

Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeMetadata
ManufacturerKongsberg Maritime AS
Model405125
Serial No.10071
Typemulti-beam echosounder
SENSORREGISTRY-LinkREGISTRY (8547)



Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeImages

Transducer Frequency

40 - 100 kHz
Metadata (Metadata Plugin)
0Frequency

Contacts

Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeContacts
Name Institution Role
FIELAX GmbHFIELAX Gesellschaft für für wissenschaftliche Datenverarbeitung mbHEngineer In Charge

...

Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeSubdevices
Name Model Serial Number SENSOR REGISTRY-
Link
Simrad EM712 Rx array 104REGISTRY (8550)
Simrad EM712 Tx array171REGISTRY (8551)

Position

Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeLocalFrame
Info The system consists of several units. Transducer arrays are installed in the keel of RV Heincke. Electronics are found in the Lotgeraeteraum. Work places are situated on the bridge and in the Messraum.
X0.0 (no unit given)
(no description given)
Y0.0 (no unit given)
(no description given)
Z0.0 (no unit given)
(no description given)

Data logging, storage and archiving

...

Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeParameters
Parameter Sensor O2ARegistry Output Type Unit
depthdepthm

...

The GPS position of the Trimble GPS receiver antenna is stored in the data files. The position is NOT centralized to the SES2000 transducers. Heave correction between the motion sensor and the transducer are calculated in the motion sensor and corrected values are transferred to the SES2000. Time synchronisation is achieved via NTP. Centralization of the GPS position to the transducer is achieved by SIS software. GPS antenna position and transducer position related to the motion sensor position as a reference point are stored in the data files. Pay attention that in case of failure of the Trimble GPS sensor the Saab GPS sensor may be used as the reference GPS source. Please contact the bridge staff for information about the GPS receiver in use. Heave correction values are only available for the Trimble GPS receiver. Heave correction between the motion sensor and the transducer is calculated in the EM712 transceiver unit. UTC time synchronisation of the transceiver unit is achieved via GPS with PPS. The PC is synchronised with UTC via the Windows-Domain-Affiliation to ensure a correct naming of the data files.
Metadata (Metadata Plugin)
0timestandard

Rawdata storage on board

The data acquisition software SIS creates raw data on the local drive of the computer. The EM712 data are not transferred to DSHIP.
Metadata (Metadata Plugin)
0Rawdata


Metadata list
|| root directory | E:\sisdata\raw\ or \\xdc\home\data\mbes\ ||
|| directory name | CruiseNo e.g. HE590 ||
|| file name | nnnn_YYYYMMDD_hhmmss_Suffix.all ||
|| Data volume (MB per day) ca | 2800 || 
|| Number of files per day ca | 50 ||

Dship

Metadata (Metadata Plugin)
0DShip
Only the water depths of the central beam are written to DShip via serial connection


Metadata list
|| Device name | Multibeam Echosounder || 
|| Parameters | Depth \[m\] ||

Data archiving on land

After consultation with the data scientist and AWI Logistics the EM712 data including meta data may be transferred to PANGAEA (https://www.pangaea.de/).
Metadata (Metadata Plugin)
0DataOnLand

Documentation

Sensorweb integration
urnvessel:heincke:heem712pu_em712sn10071
contenttypeResources

...