Comment: Automatically updated by Registry2Confluence-Transporter (aircrafts@ingestsrv1, ask o2a-support@awi.de for questions)
Note
titleAttention:

Please note that operations of the LI-7200 CO2 / H2O Analyzer requires experienced scientific staff on board the aircraft.

Summary

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeSummary

The LI-COR CO2 Analyzer is measuring CO2 in the atmosphere using the non-dispersive, closed path infrared absorption technique.

...

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeMetadata
ManufacturerLI-COR Biosciences
ModelLI-7200
Serial No.72H-0584
TypeCO2 analyser
REGISTRY-Link↪ REGISTRY (6792)


Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeImages

...

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeContacts
Name Institution Role
Jörg Jörg HartmannAlfred -Wegener-InstitutEditorWegener Institute, Helmholtz Centre for Polar and Marine ResearchJörg HartmannAlfred-Wegener-InstitutDevice Contact

Components

The LI-7200 CO2 / H2O Analyzer system comprises the gas analyser itself and an interface unit for data flow.the LI-7550 Analyzer Interface Unit

Specifications of LI-7200 (without mounting)

Metadata list

Position

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeLocalFrame
Origin Description:InfoThe LI-7200 CO2 / H2O Analyzer is installed at the cabin ceiling were it is connected to the air flow system. The interface unit is installed in a rack.
X0.0 none
(no description given)
Y0.0 none
(no description given)
Z0.0 none
(no description given)

Data logging, storage and archiving

...

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeParameters
Parameter Sensor O2ARegistry Output Type Unit
CO2 absorptanceCO2mmolμmol/m^3m3
H2O absorptancevolumetric water content mmolμmol/m^3m3
Temperaturetemperature°C
PressurepressurekPa

...

Metadata (Metadata Plugin)
0Rawdata
During flight LI-7200 data are stored within the aircraft DMS system.

Data archiving on land

After the flight LI-7200 are stored within the land system of the aircraft data managment system (
Metadata (Metadata Plugin)
0DataOnLand

DMS

...

DMS

|| Module name| B897 LICOR|| || Device name | Li_Cor 7200|| || Parameters | APres \[kPa \]; CO2AW; CO2AWO; CO2D \[mmol m-3 \]; CO2MF \[µmol/mol \]; CO2Raw; CO2SS; Cooler \[V \]; DPres \[kPa \]; Date; DewPt \[°C \]; DiagVal; DiagVal2; ErrorText; H2OAW; H2OAWO; H2OG \[g/m-3 \]; H2OMF \[µmol/mol \]; H2ORaw; H2OSS; NMEA messages LICOR 7200; Ndx; Status; Temp \[°C \]; TempIn \[°C \]; TempOut \[°C \]; Time ||
Metadata list



Documentation

Sensorweb integration
urnaircraft:bt-67:licor_72h-0584
contenttypeResources