Note |
---|
|
Please note that operations with the Core Measuring Bench the system can only be operated upon request. Operations with the MSCL-S requires experienced scientific staff on board. The system is not operated by the ship's crew. Announce operations with the Core Measuring Bench MSCL-S to AWI-Logistics prior to the cruise and clarify the data transfer after the cruise. |
Summary
Metadata (Metadata Plugin) |
---|
|
??? |
Multi-Sensor Core Loggers capture physical measurands of sediment cores automated and non-destructive. |
Image AddedImage
Manufacturer | Geotek Ltd. |
---|
Model | MSCL-S |
---|
Serial No | 14 |
---|
Type |
---|
...
Contacts
Role | Name |
---|
Principal Investigator | Frank Niessen |
Data Scientist | Catalina Gebhardt |
Engineer in Charge | Data ScientistDietmar Penshorn |
Components
Metadata (Metadata Plugin) |
---|
|
??? |
Position
Data logging, storage and archiving
Logged parameters
Central geographical ship's position and time standard
Metadata (Metadata Plugin) |
---|
|
??? Time synchronising ??? |
Metadata (Metadata Plugin) |
---|
|
??? geographical ship's position ??? |
Rawdata storage on board
Metadata (Metadata Plugin) |
---|
|
???
|
Dship
Metadata (Metadata Plugin) |
---|
|
??? data transfer to DShip. |
Data archiving on land
Metadata (Metadata Plugin) |
---|
|
??? |
Metadata list |
---|
|| File format(s) | ??? ||
|| Calibration certificates | ??? || |
Documentation
Events
The system consits of the measuring bench with a ballscrew, which pushes core section past 3 sensors measuring Gamma Density, P-wave Velocity, Magnetic Susceptibility. All sensors simultaneously acquire the data, which is displayed real-time during logging. The acquired data is stored locally in the electronics with simple user interface. |
Metadata (Metadata Plugin) |
---|
|
|| Sensor Type | Gamma Density Sensor | P-Wave System | Magnetic Susceptibility Loop Sensor MS2C ||
|| Manufacturer | Geotek Ltd. | Geotek Ltd. | Bartington Instruments||
|| Components | Gamma ray source (137-Caesium source with energies at 0.662 MeV) \\ detector \\ sensor stand mount (alignment of source/detector with center of core) | Geotek ultrasonic (230 kHz) acoustic transducers \\ Laser micrometer \\ PRT temperature Probe | Magnetic Susceptibility Loop Sensor MS2C ||
|
Data logging, storage and archiving
Logged parameters
Gamma Density, P-wave Velocity, Magnetic Susceptibility
Rawdata storage on board
Metadata (Metadata Plugin) |
---|
|
Local storage on MSCL-S electronic. Operator is in charge of data backup.
|