Summary

Two nose booms exist for measurements of turbulence in the air column. The nose booms are attached to the nose pylons of Polar 5 or Polar 6. They comprise a 5-hole probe at the tip of the nose boom. Each whole is connected to a pressure sensor - 3 differential pressure sensors and 2 static pressure sensors. Furthermore the nose booms comprise 2 temperature sensors with one de-iced housing and one not de-iced housing. Another air inlet is connected to a humidity sensor.  (see sensor specifications in chapter "Atmospheric measurements").


DMS

Metadata list
|| Module name| B719 Turbulence Noseboom 1, B851 Turbulence Noseboom 2||
|| Static Pressure Fast| ErrorText; Static Pressure Fast Raw \[V\]; Status ||
|| Dynamic Pressure | Dynamic Pressure Raw \[V\]; ErrorText; Status ||
|| Dynamic Pressure Alpha | ErrorText; Status; Differential Pressure Alpha Raw \[V\] ||
|| Dynamic Pressure Beta | ErrorText; Status; Differential Pressure Beta Raw \[V\] ||
|| Static Pressure Slow | ErrorText; Static Pressure Slow; Status ||
|| Total Air Temperature Deiced | ErrorText; Status; Total Air Temperature Deiced Raw \[Ohm\] ||
|| Total Air Temperature | ErrorText; Status; Total Air Temperature Raw \[Ohm\]||
|| Humicap | ErrorText; Relative Humidity Raw \[A\]; Status; Temperature raw \[A\] ||

...