Comment: Automatically updated by Sensor2Confluence-Transporter (aircrafts@ingest)

...

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeSummary

KT19.85II is a remote-sensing thermometer used to determine the temperature of a surface from the distance by measuring the amount of thermal radiation emitted from the surface. KT19.85II is operates in the spectral range of 9.6 - 11.5 µm. Data are stored within the DMS framework on ADA-C1Ocean Optics NIRQuest NIR Spectrometers and QE65000 Spectrometer are combined for simultaneous measurements either downward or upward looking. The NIR spectrometer cover the wavelength range between 900 and 2500 nm while operates in the visible light between 200 and 1000 nm.



Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeMetadata
Manufacturer
Heitronics
Ocean Optics
Model
KT19.85II
Serial No.n/a
Type
thermometer
Spectrometer


Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeImages
Image Removed Image Removed

No images available.

Contacts

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeContacts
Name Institution Role
Gerit BirnbaumAlfred-Wegener-InstitutEditor
Gerit BirnbaumAlfred-Wegener-InstitutDevice Contact


Available devices and Specifications

...

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeSubdevices
Name Model Type
Radiation thermometer KT19.85IIKT19.85IIthermometer
Radiation thermometer KT19.85IIKT19.85II
NIRQuest Spectrometer NIRQuestSpectrometer
NIRQuest Spectrometer NIRQuestSpectrometer
Ocean Optics QE65000 Spectrometer QE65000Spectrometer
Ocean Optics QE65000 Spectrometer QE65000Spectrometer
thermometer


Specifications of KT19.85II (without mounting)

Metadata list
|| Dimension Spectrometer (L x W x H)| 185 x 115 x 50 mm ||
|| Weight Spectrometer | 1.2 kg||
|| Power Supply| 4.5 – 5.5 VDC ||
|| Data interface | analog output (0-20mA) and serial interface (RS232)||

...

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeLocalFrame
Origin Description:The spectrometers are installed in a rack. They are connected to the sensors via fibre optic cables. The sensors can be installed upward looking in the cabin roof or downward looking at the fuselage.


Data logging, storage and archiving

...

Sensorweb integration
urnaircraft:bt-67:ocean_optics
contenttypeParameters
ParameterSensor Output TypeUnit
surface temperaturetemperature°C
surface temperature rawtemperaturemA

No parameters found in sensor.awi.de.