Sensorweb integration |
---|
urn | aircraft:bt-67:sp2_1203-048 |
---|
contenttype | Summary |
---|
|
The UHSAS SP2 is an optical-scattering, laser-based aerosol particle spectrometer for sizing particles in the 0.06 – 1 µm range. The instrument counts particles in up to 100 user-specified sizing bins, with a resolution as fine as 1 nm/bin. This high sensitivity makes the UHSAS ideal for aerosol research and filter testingideal instrument for measuring black carbon, known as soot. It is the only probe in the world that directly measures the black carbon in individual aerosol particles. Its high sensitivity and fast response makes it the premier instrument for characterizing pollution sources and measuring black carbon in snow, ice or water. The instrument measures the time-dependent scattering and incandescence signals produced by individual black carbon containing particles as they travel through a continuous-wave laser beam. Any particle traversing the laser beam will scatter light, and the black carbon component of a particle will absorb some of the laser energy until its temperature is raised to the point at which it incandesces. The amplitude of the incandescence signal is related to the amount of refractory black carbon material contained in the illuminated particle. |
Sensorweb integration |
---|
urn | aircraft:bt-67:sp2_1203-048 |
---|
contenttype | Metadata |
---|
|
Measurement Technologiesmeasurement technologies | Model |
---|
UHSAS1206036Spectrometer |
Contacts
Sensorweb integration |
---|
urn | aircraft:bt-67:sp2_1203-048 |
---|
contenttype | Contacts |
---|
|
Gerd Rohardt | Alfred-Wegener-Institute | Data Scientist | Andreas Wisotzky | Alfred-Wegener-Institute for Polar and Marine Research | Data Scientist | FIELAX GmbH | FIELAX Gesellschaft für wissenschaftliche Datenverarbeitung mbH | Engineer In Charge | Andreas Herber | AWI | Editor | Andreas Herber | AWI | Device Contact |
|
Components
The SP2 system consists of the photometer unit, which is installed in a rack. It is connected via tubing to an air inlet. An external SP2 pump ensures sustains the vacuum in the lines. Additionally, drying cartridges can be installed in the airflow. Air flow meter are connected to the system to visually check on the air flow.
...
Sensorweb integration |
---|
urn | aircraft:bt-67:sp2_1203-048 |
---|
contenttype | LocalFrame |
---|
|
device measuring unit is installed in a rack. It is connected | with via stainless steel tubes to an air inlet | installed at |
Data logging, storage and archiving
...
Sensorweb integration |
---|
urn | aircraft:bt-67:sp2_1203-048 |
---|
contenttype | Parameters |
---|
|
Parameter | Sensor Output Type | Unit |
---|
conductivity | conductivity | Hz | internal temperature | temperature | Hz | external temperature | water temperature | Hz | first voltage | voltage | V | second voltage | voltage | V | Salinity | salinity | PSUblack carbon mass derived from incandescence | black carbon | ng/m3 | single-particle laser incandescence | radiation | none | single-particle light scattering | particle number concentration | none |
|
Rawdata storage on board
Metadata (Metadata Plugin) |
---|
|
During flight SP2 data are stored within the photometer unit. |
...
Sensorweb integration |
---|
urn | aircraft:bt-67:sp2_1203-048 |
---|
contenttype | Resources |
---|
|
|